DVIO 1.8 Error Codes
Error Code Id Description Hardware
0 0x00 DVIOC_ERR_DDS_OK No Error
6 0x06 DVIOC_ERR_DDS_UNKNOWN Unknown Error(including UART communication
error)
17 0x11 DVIOC_ERR_DDS_TNF_1 Link chip incorrect responding µPD72893, Link
18 0x12 DVIOC_ERR_DDS_TNF_2 No link register access or link reset failed µPD72893, Link
23 0x17 DVIOC_ERR_DDS_TNF_7 Link reset failed µPD72893, Link
38 0x26 DVIOC_ERR_DDS_TNF_16 Expecting no 1394 node with GUID connectivity,
while detecting connection
39 0x27 DVIOC_ERR_DDS_TNF_17 Expecting 1394 node with GUID connectivity, while
not detecting connection
48 0x30 DVIOC_ERR_DDS_UPINTRAM
A
Internal ram problem in address lines µPD78F0988,
Wrapper
50 0x32 DVIOC_ERR_DDS_UPEXTRA
MA
External ram problem in address lines µPD4564163G5,
SDRAM
51 0x33 DVIOC_ERR_DDS_UPEXTRA
MD
External ram problem in data lines µPD4564163G5,
SDRAM
58 0x3A DVIOC_ERR_DDS_ROMCHK Checksum of codespace 0x0000-0x1f80, 0x2000-
0xeffd is not correct
µPD78F0988,
Wrapper
244 0xF4 DVIOC_ERR_LINK_HWPHY PHY chip not responding(PHY down report received) µPD72852, Phy
245 0xF5 DVIOC_ERR_LINK_HWLINK LINK chip not responding µPD72893, Link