C. Settings
C.1.F Temporary change setting path: Home> Settings> Climate> Temporary
It is possible to input a temporary change (negative or positive) in these sets for a prefixed timing.
After that the changed set will go back to initial value.
When the temporary change set is activated (by clicking on Active key) the remaining time of duration
of change will be displayed. By pressing the End key the change of set will be stopped.
Duration of the temporary change. When set to 23:59 the change(s)
will remain active until the next starting cycle is carried out (C.9).
Variation of the ventilation set. If ‘Ventilation set’ (C.1.2) is set to
25°, entering +1.0° will increase the operating ventilation set to 26°.
Variation of the heating set. If ‘Heating set’ (C.1.1) is 23°, entering
+1.0° will increase the operating heating set to 24°.
Variation of the air exchange set (minimum ventilation in M3/hr/kg).
The entered percentage change is a percentage of the current air
exchange setting.
Example, if ‘Air exchange’ (C.1.3) is set to 10%, entering a change
of +20% will increase the operating air exchange to 12%
Duration of change
(Range: 0
h
.00
m
...23
h
.59
m
)
‘Ventilation’ change
(Range: -5.0°...0.0°...5.0°)
‘Heating’ change
(Range: -5.0°...0.0°...+5.0°)
‘Air exchange chan.
(Range: -50%...0%...+100%)