70
D. Installation - Bird weighing
D.3 Bird weighing
Path: Home> Installation> Bird weighing Only if Bird weighing is active.
D.3.1 Load cell data
Path: Home> Installation> Animal weighing> Load cell data
Choose between Chicken or Turkey.
Full scale weight of the load cell
(see technical specification of the load cell).
Balance loading cell data (see technical features of the load cell).
Perform a ‘Calibration’ to automatically record this value.
Weight tare.
Perform an ‘Automatic tare’ to automatically record this value.
Filter time of the weighing system.
Plate bird type
(Range: Chicken...Turkey)
Cell full-scale
(Range: 0g...35000g...100000g)
Cell sensitivity
(Range: 0.8...2.000...3.300)
Tare weight
(Range: 0g...5800g...30000g)
Filter seconds
(Range: 0.0...0.2”...10.0”)
According to what was set in Configuration (see par. D.C) Xfarm can control 1 weigher plate:

Table of Contents