D.2.1.3 Silo weighing
Path: Home> Installation> Feeding> Feed weighing> Silo weighing
Number of cells mounted on the silo.
Kg full scale of the loading cell (see technical features of the load cell).
Balance loading cell data (see technical features of the load cell).
Perform a ‘Calibration’ to automatically record this value.
Kg weight tare.
Perform an ‘Automatic tare’ to automatically record this value.
Filter time of the weighing system.
Number of load cells
(Range: 0...4...8)
Cells full-scale
(Range: 0k...5000k...100000k)
Cells sensitivity
(Range: 0.8...2.000...3.300)
Tare weight
(Range: 0k...100000k)
Filter seconds
(Range: 0.0...1.0”...10.0”)