30
D. Installation - Heating
Influence of Blocks on Heating operation.
Normal Heating’s working can be influenced by some block condition (par. D.1.1.2).
The intervention of those blocks is visualized in Zoom on heating and in Climate blocks (par. F.1).
Foreword
According to what was set in Configuration (see par. D.C) Xfarm can control up to 3 Heaters.
The Temperature Settings of the Heating (relative set) refer to the set Heating programmed in Settings
> Climate (par. C.1): when changing the main function set (Heating), the sub-functions change
accordingly. This Set can be set by Calendar (par. C.4).
For example with a set Heating= 20.0° and a Heating 1 (relative set) = 1.0° the set of temperature
working of the Heating 1 will be of 21.0° (20.0° + 1.0°).
D.1.1 Heating installation parameters
Path: Home> Installation> Climate> Heating
HEAT
2
HEAT
1
Heating 1 (relative set)
Heating indoor temperature
of the relative probe
Heating
Set referred to the Heating set programmed in Settings>Climate
This Set can be set by Calendar (see par. C.4)
When this parameter has a
negative value, its deducted
from the Heating set.
Heating 2 (relative set)
HEAT
3
Heating 3 (relative set)