31
D. Installation - Heating
D.1.1.1 Temperature set
Path: Home> Installation> Climate> Heating> Temperature set
These parameters refer to the functioning sets of Heating.
Temperature set of Heating 1 referred to the Heating set
programmed in Settings>Climate (par. C.1).
Temperature set of Heating 2 referred to the Heating set
programmed in Settings>Climate (par. C.1).
Temperature set of Heating 3 referred to the Heating set
programmed in Settings>Climate (par. C.1).
Heating temperature differential.
Heating 1
(Range: -30.0°...0.0°...30.0°)
Heating 2
(Range: -30.0°...0.0°...30.0°)
Heating 3
(Range: -30.0°...0.0°...30.0°)
Heating differential
(Range: 0.0°...0.2°...30.0°)
Example
- Heating = 28.0° (programmed in Settings>Climate par.C.1)
- Heating 1 (relative set) = 1.0°
- Heating differential = 0.2°
As per the above settings the heater starts at 29.0° (28.0+1.0) and stops at 29.2° (28.0+1.0+0.2).
Same as Heating 2 and Heating 3, but referred to the set Heating 2 and Heating 3.
HEAT 1
ON
OFF
Heating
differential
Heating 1 probe
temperature
Set referred to the Heating set programmed in
Settings>Climate (par.C.1)
Heating 1 (relative set)