SD300
POWER ELECTRONICS
110
DESCRIPTION OF PROGRAMMING PARAMETERS
Screen
Description
Default
value
Range
Function
Set
on
RUN
dr.9
Control type
V/Hz
0 to 6
NOTE: Comes from the previous page.
OPT.
DESCR.
FUNCTION
4
S-less1
Sensorless vector control
is an operation to carry out
vector control without the
rotation speed feedback
from the motor but with an
estimation of the motor
rotation speed calculated
by the drive. Sensorless
vector control can
generate greater torque at
a lower current level than
V/Hz control.
6
PM
Sensor-
less
It allows selecting the
control for permanent
magnet synchronous
motors.