Installation and Operation Manual Page 59 of 104
(PVI-3.8/4.6-I-OUTD-US Rev.: 1.1)
5.1.2 Internally Logged Data
AURORA stores the following data internally:
Total and partial counter of grid connection time
Total and partial counter of energy transferred to the grid
Energy produced daily (365 values)
Energy transferred to the grid every 10 seconds for the last 8,640 periods of 10
seconds (which on average cover more than 2 days of logged data)
Last 100 fault conditions with error code and time stamp
The first two types of data are displayed on the LCD display and through the RS-485
interface, while all other data can be displayed only through the RS-485 interface.