Installation and Operation Manual Page 91 of 104
(PVI-3.8/4.6-I-OUTD-US Rev.: 1.1)
6.2 Measurement Accuracy
Every measurement should consider possible errors.
The tables below show the following information for each reading:
the units of measurement;
the range;
the resolution.
Resolution
Name of
measured
variable
Unit of
measure-
ment
Display Value
Maximum
percentage of
error
Input voltage PV
No. 1
VP1 Vdc 1 V 600mV
2%
Input voltage PV
No. 2
VP2 Vdc 1 V 600mV
2%
Input current PV
No. 1
IP1 Adc 0.1 A 25mA 2%
Input current PV
No. 2
IP2 Adc 0.1 A 25mA 2%
Output power PV
No. 1
Pin1 W 1 W 10W 2%
Output power PV
No. 2
Pin2 W 1 W 10W 2%
Output voltage Vout V 1 V - 2%
Output current Iout A 0.1 A - 2%
Output power Pout W 1 W - 2%
Frequency Freq Hz 0.01 0.01
0.1%