EasyManuals Logo

Powtran PI9000 series User Manual

Powtran PI9000 series
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #238 background imageLoading...
Page #238 background image
Appendix I
232
Command address
Command content
2004
0 to 7FFF indicates 0 to 100
Inverter fault description:
Inverter fault address:
Inverter fault information:
8000
0000: No fault
0001: Inverter unit protection
0002: Acceleration overcurrent
0003: Deceleration overcurrent
0004: Constant speed overcurrent
0005: Acceleration overvoltage
0006: Deceleration overvoltage
0007: Constant speed overvoltage
0008: Control power failure
0009: Undervoltage fault
000A: Inverter overload
000B: Motor Overload
000C: Input phase loss
000D: Output phase loss
000E: Module overheating
000F: External fault
0010: Communication abnormal
0011: Contactor abnormal
0012: Current detection fault
0013: Motor parameter auto tunning fault
0014:Encoder/PG card abnormal
0015: Parameter read and write abnormal
0016: Inverter hardware fault
0017: Motor short to ground fault
0018: Reserved
0019: Reserved
001A:Running time arrival
001B: Custom fault 1
001C: Custom fault 2
001D: Power-on time arrival
001E: Load drop
001F: PID feedback loss when running
0028: Fast current limiting timeout
0029: Switch motor when running fault
002A: Too large speed deviation
002B: Motor overspeed
002D: Motor overtemperature
005A: Encoder lines setting error
005B: Missed encoder
005C: Initial position error
005E: Speed feedback error
Data on communication failure information description (fault code):
Communication fault address
Fault function description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Powtran PI9000 series and is the answer not in the manual?

Powtran PI9000 series Specifications

General IconGeneral
BrandPowtran
ModelPI9000 series
CategoryInverter
LanguageEnglish

Related product manuals