EasyManuals Logo

Powtran PI9000 series User Manual

Powtran PI9000 series
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #53 background imageLoading...
Page #53 background image
Chapter 5 Function parameter
47
No.
Code
Parameter name
Setting range
Factory
setting
Change
Reference
page
130.
F2.13
SPA output delay
time
0.0s to 3600.0s
0
.
0s
115
131.
F2.14
Relay 2 output delay
time
0.0s to 3600.0s
0
.
0s
115
132.
F2.15
DO output terminal
active status
selection
Units digit: SPB
switching quantity
0: positive logic
1: anti-logic
Tens digit: Relay 1
Hundreds digit:
Hundreds digit:
Undefined
Thousands digit: SPA
Ten thousands digit:
Relay 2
00000
115
133.
F2.16
DA1 zero bias
coefficient
-100.0% to +100.0%
0.0%
116
134.
F2.17
DA1 gain
-10.00 to +10.00
1.00
116
135.
F2.18
DA2 zero bias
coefficient
-100.0% to +100.0%
0.00%
116
136.
F2.19
DA2 gain
-10.00 to +10.00
1.00
116
5-1-5.F3 Group - Start and stop control group
No.
Code
Parameter name
Setting range
Factory
setting
Change
Reference
page
137.
F3.00
Start-up mode
0:
Direct startup
1:
Speed tracking
restart
2: Pre-excitation start
(AC asynchronous
motor)
0
116
138.
F3.01
Speed tracking
mode
0: start from stop
frequency
1: start from zero
0
116

Table of Contents