Chapter 5 Function parameter
65
No.
Code
Parameter name
Setting range
Factory
setting
Change
Reference
page
305.
FA.05
Torque control
forward maximum
frequency
0.00Hz to
F0.19(maximum
frequency)
50.00Hz
151
306.
FA.06
Torque control
backward maximum
frequency
0.00Hz to F0.19
(maximum
frequency)
50.00Hz
151
307.
FA.07
Torque filter time
0.00s to 10.00s
0.00s
151
5-1-13.Fb Group - Control optimization parameters
No.
Code
Parameter name
Setting range
Factory
setting
Change
Reference
page
308.
Fb.00
Fast current limiting
manner
0: disable
1: enable
1
151
309.
Fb.01
Undervoltage point
setting
50.0% to 140.0%
100.0%
152
310.
Fb.02
Overvoltage point
setting
200.0V to 2500.0V
-
152
311.
Fb.03
Deadband
compensation mode
selection
0: no compensation
1: compensation
mode 1
2: compensation
mode 2
1
152
312.
Fb.04
Current detection
compensation
0 to 100
5
152
313.
Fb.05
Vector optimization
without PG mode
selection
0:
no optimization
1: optimization
mode 1
2: optimization
mode 2
1
153
314.
Fb.06
Upper limiting
frequency for
DPWM switching
0.00Hz to 15.00Hz
12
.00Hz
153
315.
Fb.07
PWM modulation
manner
0: asynchronous
1: synchronou
0
153