Chapter 5 Function parameter
62
No.
Code
Parameter
name
Setting range
Factory
setting
Chan
ge
Reference
page
action selection
283.
F8.27
Recovery
judgment
voltage of
momentary
power cut
50.0% to 100.0%
90%
146
284.
F8.28
Recovery
voltage
judgment time
of momentary
power cut
0.00s to 100.00s
0.50s
146
285.
F8.29
Judgment
voltage of
momentary
power cut
action
50.0% to 100.0%
(standard bus voltage)
80%
146
286.
F8.30
Load drop
protection
selection
0: Invalid
1: Valid
0
147
287.
F8.31
Load drop
detection level
0.0 to 100.0
10%
148
288.
F8.32
Load drop
detection time
0.0 to 60.0s
1.0s
148
289.
F8.33
The motor
temperature
sensor type
3
0: Invalid;1PT100 detect
0
148
290.
F8.34
Motor
overheating
protection
threshold
3
0200
110
148
291.
F8.35
Motor
overheating
forecasting
warning
threshold
3
0200
90
148