ProgrammerManual PTXS828
Chapter6IPDSExceptionReportingCodes 224 260071001A
Explanation: There is an invalid or unsupported
Load Copy Control keyword in the group entry.
Alternate Exception Action: None.
Count
Explanation:
1. The number of bytes in Load Copy Control
group is not a multiple of two byte pairs.
2. The number of bytes in Load Copy Control
group is not a valid or supported value.
Alternate Exception Action: None.
X'023601' Invalid or Unsupported Load Copy
Control Simplex/Duplex Parameter
Explanation: The LCC command simplex/duplex
parameter is invalid or unsupported.
Alternate Exception Action: If invalid, none. If
unsupported, the printer prints simplex.
X'023A02' Maximum Number of Fonts
Allowed by the Printer Exceeded
Explanation: An attempt was made to
download more fonts than the printer can
support.
Alternate Exception Action: None.
X'023F02' Font Index Not Loaded
Explanation:
1. The font inline sequence in Load Font
Equivalence command is not supported or not
supported with the current Text Orientation.
2. The Font Index specified in a Load Font
Equivalence command called out by a Set Coded
Font Local text control is not loaded.
Alternate Exception Action: None.
X'024201' WIC Pel Count < Minimum
Required
Explanation: The Target or Source Pel Count
value on the Write Image Control command is
less than 1.
Alternate Exception Action: None.
X'024301' WIC Pel Count > Maximum Allowed
Explanation: The Target or Source Pel Count value
on the Write Image Control command is greater
than the valid or supported maximum.
Alternate Exception Action: None.
X'024401' WIC Scan Count < Minimum
Required
Explanation: The Target or Source Scan Count
value on the Write Image Control command is
less than 1.
Alternate Exception Action: None.
X'024501' WIC Scan Count > Maximum Allowed
Explanation: The Target or Source Scan Count
value on the Write Image Control command is
greater than the valid or supported maximum.
Alternate Exception Action: None.
X'024601' Invalid WIC Source Image Format
Explanation:
1. The Compression Algorithm value (Byte 8) is
not a valid or supported value.
2. The (Pel) Data Format value (Byte 9) in the
Write Image Control command is not X'00'.
Alternate Exception Action: None.
X'024701' Invalid WIC Scale Factor Value
Explanation:
1. The Pel Count Scale Factor value on the Write
Image Control command is not a valid or supported
value.
2. The Scan Count Scale Factor value on the Write
Image Control command does not equal the Pel
Count Scale Factor.
Alternate Exception Action: None.
X'024702' Invalid LFE Font Inline Sequence
Explanation: The Font Inline Sequence
parameter in a Load Font Equivalence
command is not a valid or supported value.
Alternate Exception Action: None
X'024801' Invalid WIC Scan Line Direction
Explanation: The Scan Line Direction parameter
value on the Write Image Control command is not a
valid or supported value.
Alternate Exception Action: None.
X'024802' Invalid Font Section Number in
LSS command
Explanation: The section number specified in
the LSS command is not a valid or supported
value.
Alternate Exception Action: None.
