User Guide
DVS-21
02/2018 • V.1.0 L. Wolle
25/131
© 2017 ProCom
®
Professional Communication & Service GmbH • Technical changes reserved.
Add. fault report output
The standard fault report of a system is made by means of the SV01 module.
Should a general fault be processed in addition, this takes place by using a
Line or Flags.
Check call stations (0=not)
Connected stations are interrogated at the programmed interval. If it is no
longer possible to address a station, then an FSK fault report is triggered on
the associated port of the 4NSA module and a related general fault report on
the SV01.
Speech time limit
(0=none)
Active intercom calls are disconnected after the specified time. It is only
possible to continue the call for the set time once a new connection has been
established.
Fault report OR Flag
This Flag triggers an SV01 general fault if it is activated.
Battery control, additional output
System clock
automatic switch-over to West European summertime
Activates the internal correction of the system clock according to the official determination of Summer-
/Winter-time change-overs.