Professional Communication & Service GmbH • Technical changes reserved.
There is an option of setting standard values for a level. These settings spare the need for unnecessary
new entries when installing new stations, with the prerequisite that all your stations that are to be
configured will use the same level throughout. The Night standard values are used as the default for
speech settings as well as for amplifier configurations.
By using the All xxx Standard Level assignment buttons, all available stations and amplifiers are set to the
specified standard level.
Definition of the level values
Normal-Level
is the level that is used during a call
Call-Level
is the level that is used when establishing a connection. Generally this level value is set
higher, in order to gain the attention of the subscriber by a greater volume when first
addressing him/her.
After a freely programmable Intercom interval time (no AF transmission, see Stations), the Call-Level is
reactivated for a new call.
The min. and max. specifications are of significance for automatic volume adjustment and determine the
bandwidth in which the level can vary. Should a fixed level be used, then the min. specification is used as
a basis.