Specification of the precise duration of the recording(Unit = value x 50, 100, 150 or
200ms)
Pause between automatic repeats (Unit = value x 50ms)
[IN] The program can be turned off by this flag or switching on can be prevented.
[IN] The program can be switched on by this flag.
9.4 IC Intercom
Program to establish local IC connections
For one connection between two call stations, two programs are used. Each program is programmed on
a key of the call stations involved.
The program is compatible with the IC Intercom gate program! Unilaterally-controlled connections can be
set up in this way.
In each case the association arises from the Station number of Destination call station. Specification of
the Destination call station is required in both programs. All further specifications are optional.
Handling of priorities (see Section 9.1)
Audio compression method by which the codec handles the actual connection.
The options are: µLaw (default), ADPCM (7kHz) and aLaw (see Section 9.1)
The connection is established and remains one-sided until the key is pressed again.
The remote station can reverse the direction and reply. The priorities can be the
same.
Selects the type of call station (ProCom- or Analog- call stations).
Input/call station (Setting Own)
Address and port of the module to which the call station is connected and the line
(key) that is used. (4NSA)
Input/call station (Setting Analog)
Address and port of the module to which the AF line of the call station is connected.
(4NPA)
Address, port and line of the module to which the control line of the call station is
connected. (24LI)
Time for the key is illuminated (flashing) after missed calls
The address of the destination is specified directly and not determined via the
Station number.
Unique number of the Destination call station