Warning of feed chemical spraying around
n The metering pump may generate a multiple of its nominal
pressure. Hydraulic parts may rupture if a pressure line is
blocked.
n Install a relief valve in the pressure line downstream of the
metering pump.
CAUTION!
Warning of feed chemical spraying around
An unsuitable feed chemical can damage the parts
of the pump that come into contact with the chem‐
ical.
– Take into account the resistance of the wetted
materials and the ProMinent Resistance List
when selecting the feed chemical - see the
ProMinent Product Catalogue or visit ProMi‐
nent.
CAUTION!
Danger of injury to personnel and material damage
The use of untested third party components can
result in injury to personnel and material damage.
– Only fit parts to metering pumps that have
been tested and recommended by ProMinent.
CAUTION!
Danger from incorrectly operated or inadequately
maintained pumps
Danger can arise from a poorly accessible pump
due to incorrect operation and poor maintenance.
– Ensure that the pump is accessible at all times.
–
Adhere to the maintenance intervals.
Danger from incorrect dosing
n The metering behaviour of the pump changes if a different
liquid end size is fitted.
n Reprogram the pump in the
‘Menu / Information
è
Settings
è
System
è
Replace head type’
menu.
CAUTION!
Warning against illegal operation
Observe the regulations that apply where the
device is installed.
n Cover of the slot for relays and optional modules - see the
chapter entitled "Overview of equipment and control elements"
Customers should only remove the cover of the slot for relays and
optional modules and/or a relay or optional module in line with the
supplementary instructions for the relays and optional modules.
Customers should only remove the dosing head in accordance with
the "Repair" chapter.
Isolating protective equipment
Safety chapter