11.2.1
‘Operating mode’
‘Menu / Information
è
Settings
è
Operating mode
è
...’
11.2.1.1
‘Manual’
‘Menu / Information
è
Settings
è
Operating mode
è
Manual’
‘Manual’
operating mode lets you operate the pump manually.
The capacity and/or stroke rate and stroke length can be set in the
continuous displays in this operating mode.
11.2.1.2
‘Contact’
‘Menu / Information
è
Settings
è
Operating mode
è
Contact
è
...’
‘Contact’
operating mode allows you to trigger individual strokes or
a series of strokes.
You can trigger the strokes via a pulse sent via the "External con‐
trol" terminal.
The purpose of this operating mode is to convert the incoming
pulses into strokes with a step-down (fractions) or small step-up or
also 1:1.
CAUTION!
The pump maintains the stroke rate when
changing over from
‘Manual’
operating mode to
‘Contact’
operating mode.
The maximum stroke rate can be set in ‘Contact’
operating mode. It should normally be set to
12,000 strokes/hour.
If the gaps between the pulses (e.g. from a contact water meter)
slowly change, you can set the pump to
‘Adaptive
è
On’
- the
pump will then meter more evenly.
You can also activate the
‘Memory’
function extension ("memory"
identifier). When
‘Memory’
is activated, the pump adds up the
remaining strokes, which could not be processed, up to the max‐
imum capacity of the stroke memory of 999,999 strokes. If this
maximum capacity is exceeded, the pump goes into fault mode.
CAUTION!
– Only with
‘Memory’
-
‘off’
: If you press
[STOP/START]
or empty the contact memory
(
‘Menu / Information
è
Service
è
Clear counters’
) or the "Pause" function is
activated, the
‘Memory’
is cleared.
Contact - adaptive
Memory - Pulses not yet processed
Set up /
‘Menu’