17.5 Electrical data
Specification Value
Nominal power, approx. 78 W
Switch on peak current, (within approx. 50 ms
falling
8 ... 4 A
prevention T 3.15 A *
* 250 V (1.5kA), Order no. 732414
Fuses must have VDE, UL and CSA certification.
17.6
Temperatures
Data Value Unit
Storage and transport temperature: -10 ... +50 °C
Ambient temperature in operation
(power end/drive and control):
-10 ... +45 °C
Data Value Unit
Liquid end temperature -10 ... +40 °C **
* long term at max. operating pressure, dependent on the ambient
temperature and the feed chemical temperature
** with PVT and SST: -10 ... +50 °C
Material version Value Unit
NPT 60 °C
PVT 120 °C
SST 120 °C
* Temp. max., for 15 min at max. 2 bar, dependent on the ambient
and feed chemical temperatures
17.7
Climate
Air humidity, max. 95% relative humidity, non-condensing.
Exposure in a humid and changing climate:
FW 24 according to DIN 50016
Wet location: No
Design: 100 - 230 V ±10%, 50/60 Hz
Pump, fully assembled
Liquid end, long-term*
Liquid end, short-term*
Wet location
Technical data
118

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent gamma XL and is the answer not in the manual?

ProMinent gamma XL Specifications

General IconGeneral
BrandProMinent
Modelgamma XL
CategoryWater Pump
LanguageEnglish

Related product manuals