11.2.4 Metering
‘Menu / Information
è
Settings
è
Metering
è
...’
11.2.4.1
‘Discharge stroke’
‘Menu / Information
è
Settings
è
Metering
è
Discharge stroke
è
...’
In the
‘Settings’
-
‘Discharge stroke’
sub-menu, you can precisely
match the pump metering flow over time to the requirements of the
particular application.
This ensures that users can set the optimum discharge stroke for
their application, as required:
Pos.* Discharge stroke Application
A.
‘optimum’
For maximum precision when metering and the very best results
with internal pressure measurement and special functions.
B.
‘fast’
For a fast discharge stroke.
C.
‘very fast’
For a super-fast discharge stroke.
D.
‘sine mode’
The duration of the discharge stroke is dependent on the stroke rate
for a long, sine-shaped discharge stroke.
E.
‘continuous’
For a continuous discharge stroke e.g. for bottling processes. The
duration of the discharge stroke is dependent on the stroke rate.
F.
‘DFMa’
For optimum operation with a flow meter DulcoFlow
®
DFMa.
* see following drawing.
Set up /
‘Menu’
56

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent gamma XL and is the answer not in the manual?

ProMinent gamma XL Specifications

General IconGeneral
BrandProMinent
Modelgamma XL
CategoryWater Pump
LanguageEnglish

Related product manuals