MVI56-PDPMV1 ♦ ControlLogix Platform Mailbox Messaging
PROFIBUS DPV1 Master User Manual
Page 157 of 251 ProSoft Technology, Inc.
Message Information
Refer to Acyclic Message Status Word (page 170).
Station Type [0 … 126]
00h: Slave Station
01h: Master Station not yet ready for Token ring (station only physically at the
bus)
02h: Master Station ready to enter Token ring (there is not yet any Token
transmission)
03h: Master Station in Token Ring (Token transmission through the station)
04h: Station does not exist
Fault Information
If "Invalid Other" is returned in the Message Information word in the header of the
response, information about the fault can be found here. Refer to Acyclic
Message Status Word (page 170).
0AH00: Failed to build Live List.
FF00h: Module offline (not initialized or no valid database)