Page 62
To read a parameter value, send the command
/Pxxx where xxx is the parameter you wish to read, and the Sludge Finder 2 will
respond with the parameter value.
To set a parameter, send the command
/Pxxx:yy where xxx is the parameter number, and yy is the value you wish to set
it to.
Other commands you can use are:
/LEVEL1 (shows current level of point 1)
/LEVEL2 (shows current level of point 2)
/DISTANCE1 (shows current level of point 1)
/DISTANCE2 (shows current level of point 2)
/TEMP1 (shows current temperature of point 1)
/TEMP2 (shows current temperature of point 2)
/CURRENTOUT1 (shows the mA output value for mA output 1)
/CURRENTOUT2 (shows the mA output value for mA output 2)
Please consult Pulsar Process Measurement or contact your local Pulsar
representative for further details and a full list of available commands.