EasyManua.ls Logo

Qlogic SANbox 5600 Series Interface Manual

Qlogic SANbox 5600 Series
408 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #90 background imageLoading...
Page #90 background image
6 – Port Configuration
Modifying Port Operating Characteristics
6-8 59183-03 A
S
You can configure all ports based a specified source port using the
Set Config Ports command. The following example configures ports 0–19 based
on port 3.
SANbox #> admin start
SANbox (admin) config edit
SANbox (admin) #> set config ports 3
.
.
.
SANbox (admin-config)#> config save
SANbox (admin)#> config activate
SANbox (admin)#> admin end
The following example temporarily changes the port 1 administrative state to
Down:
SANbox #> admin start
SANbox (admin) #> set port 1 state down

Table of Contents

Other manuals for Qlogic SANbox 5600 Series

Questions and Answers:

Qlogic SANbox 5600 Series Specifications

General IconGeneral
ModelSANbox 5600 Series
Form Factor1U
Switch TypeFibre Channel
Supported ProtocolsFibre Channel
Management InterfaceWeb-based GUI, CLI, SNMP
Port Speed1 Gbps, 2 Gbps
Fabric TypeFibre Channel
Hot SwappableYes
RedundancyDual power supplies, hot-swappable
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Humidity10% to 90% non-condensing

Related product manuals