Page 82 of 82 Interface
Table 3-4: IEEE & RS-232 Commands (continued)
Command Function Parameter(s)
VIEW:
TEST? View the test’s programmed parameters
TEST View the single-test’s parameters nn
The format of the returned data is as follows:
Mode:<tab><No Test Programmed, AC Total Current, AC Real Current,
AC Imag Current, DC Current, IR, or GC Only><CR>
Volt:<tab><n.nnnKV><CR>
Hi Limit:<tab><nn.nnnmA><CR>
Low Limit:<tab><nn.nnnmA or Off><CR>
Arc Limit:<tab><nn.nnnmA or Off><CR>
Ramp Time:<tab><nnn.nsec or Off><CR>
Hi Lim Ramp:<tab><nn.nnnmA or Off><CR>
Low Lim Ramp:<tab><nn.nnnmA or Off><CR>
Dwell Time:<tab><nnn.nsec or Off><CR>
Test Time:<tab><nnn.nsec or Continuous><CR>
Fall Time:<tab><nnn.nsec or Off><CR>
Frequency:<tab><50Hz or 60Hz><CR>
Gnd Continuity:<tab><nn.nnOhms><CR>
Note that only valid parameters are returned for the selected mode (see the
previous table).
SEQuence View the sequence n
The format of the returned data is as follows:
S1:1 Test: <nn or skip or none><CR>
S1:2 Test: <nn or skip or none or calc><CR>
Calc: <AC Total Current, AC Real Current, or AC Imag
Current><CR>
Calc Hi Lim: <n.nnnmA><CR>
Calc Low Lim: <n.nnnmA><CR>
S1:3 Test: <nn or skip or none or calc><CR>
Calc: <AC Total Current, AC Real Current, or AC Imag
Current><CR>
Calc Hi Lim: <n.nnnmA><CR>
Calc Low Lim: <n.nnnmA><CR>

Table of Contents