EasyManua.ls Logo

QubicaAMF BES X - Upload Animations to 4 HD;5 HD-CPU Units

Default Icon
164 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
How to BES X Installation Manual, Rev.9, Jun 2018
140
140 P/N: 400288005
14.1 - How to turn on/off the pair of lanes
QubicaAMF suggest to turn off the scoring system every night to save power.
14.1.1 - Turning ON the system.
This is the procedure to follow in order to turn on the system in the mornings for BES X Scoring systems:
Turn on Front-desk 1 / Terminal 1;
If a separate server is present it should already be ON;
Turn on overhead monitors;
Wait until the Front-desk1 / Terminal1 boot up completely (note that in the case of ConquerorPRO
backup you should wait until the end of it) then turn on the 4HD/5HD-HUB units;
Turn on all other ConquerorPRO Front desks / Terminals.
In case of LCD monitors controlled from the Front Desk (AccuVision, etc…) turn on the monitors
from the Special Functions of the Front Desk.
14.1.2 - Turning OFF the system.
This is the procedure to follow in order to turn off the system in the nights for BES X Scoring systems:
In case of LCD monitors controlled from the Front Desk (AccuVision, etc…) turn off the monitors
from the Special Functions of the Front Desk.
Close ConquerorPRO in all the stations;
Turn off Front-desk1 / Terminal1;
Accept “Execute daily task”;
NOTE: if a separate server is present, or in the case you purchase a web-booking system the
ConquerorPRO server computer should be kept on at all times;
Turn off all the other Front desks / Terminals;
Turn off the 4HD/5HD-HUB units from the Electronic sub-panel breakers;
Turn off Overhead Monitors from the Electronic sub-panel breakers.
14.2 - How to boot the BES X system in emergency (in the
case of a ConquerorPRO server PC crash)
If the ConquerorPRO server is down and there are either no other ConquerorPRO licensed computers
available (it is not possible to convert a Front Desk 2, 3, etc…, or convert the Back Office into a
ConquerorPRO server) it is possible to reboot lanes in emergency.
To boot the BES X system in emergency:
Keep the ConquerorPRO server turned off, or disconnect the network cable from the Scoring NET
network card (the secondary network card).
Reset (turn off and on) all the 4HD/5HD-HUB units by unplugging the power units;
The 4HD/5HD-CPU units boot without IP address, displaying a RED background on the lane
monitors.
In emergency the lanes can be opened using either the lane consoles keypads (EasyKey) or LCD touch
screens (SuperTouch).

Table of Contents

Related product manuals