Scoring network BES X Installation Manual, Rev.9, Jun 2018
70
70 P/N: 400288005
5.2.2 - Centers with: up to 12 lanes, MMS or TCS or Q-COM and
single channel video server.
Two 8 ports network switches will be supplied by QubicaAMF for this configuration.
The connections for the main scoring network switch are:
1 port for the home-run cable;
1 port for the slave scoring network switch;
6 ports for MMS or Q-DAC units.
The connections for the slave scoring network switch are:
1 port for the main scoring network switch;
1 port for the single channel video server;
6 ports for 4HD/5HD-HUB units.
The 4HD/5HD-HUB units have to be connected to the slave scoring network switch via standard patch
network cables. Refer to tables T.20.079 and T.20.096 for standard installations or to table T.20.082 if XLi
pinspotters with safety kit are present for the correct patch cables’ length.
The single channel video server, if present, have to be connected to the slave scoring network switch using
a Cat.5e solid network cable.
The slave scoring network switches have to be connected to the main scoring network switch using the
provided network cable.
The second network card of the ConquerorPRO server have to be connected to the main scoring network
switch using a Cat.5e solid network cable.
The MMS or Q-DAC units have to be connected directly to the main scoring network switch using the
provided network cable.
This configuration is described in the table T.20.092.