BES X system configurations BES X Installation Manual, Rev.9, Jun 2018
30
30 P/N: 400288005
3.2 - EasyKey console brief description
The EasyKey console is the keyboard console. It gives access to the basic on-lane functions of the BES X
system.
The EasyKey console is InterCom ready. This fact does not means that the InterCom system will be available
on the lanes, because the InterCom have to be purchased separately (Q-Com system).
During the operation of the lanes on the EasyKey console will be highlighted only the buttons that have a
function in the context.
During the boot of the system the EasyKey console will light different buttons (letters and numbers), then a
single character will blink for a few seconds:
“O” button blinking: the EasyKey console is configured to run in the “Twin” configuration, so two
EasyKey consoles on the same pedestal;
“Q” button blinking: The EasyKey console is configured to operate as a single console with a single
pedestal (one EasyKey console per lane with a single pedestal or one EasyKey console per pair of
lanes).
3.3 - EasyKey Pair console
In this configuration on each pair of lanes there will be installed:
the camera (Q-Vision or T/M-Vision);
the pinspotter interface;
other optional LCOM devices (Bumper interface, Q-FOUL, TMR, etc…);
one 4HD/5HD-HUB;
one 4HD/5HD-CPU;
the overhead monitors (i.e.: two overhead monitors);
one EasyKey console.
The camera, the pinspotter interface and the other optional LCOM devices are connected to the 4HD/5HD-
HUB via the LCOM cable (Refer to section “6 LCOM Line” for further information).
The L1 port of the 4HD/5HD-CPU is connected to the L1 port of the 4HD/5HD-HUB via a network cable.
Each overhead monitor is connected to the proper port of the 4HD/5HD-CPU unit with a HDMI cable. If the
monitors does not support commands by the HDMI, a serial communication cable (P/N: 288401007) has to
be installed between the overhead monitor and the 4HD/5HD-CPU in order to be controlled directly from a
ConquerorPRO computer.
The EasyKey Pair is a single EasyKey console on a single stand installed on each pair of lanes.
The EasyKey console is connected to the L4 port of the 4HD/5HD-HUB through a network cable (yellow
cable).
Each console has to be connected to ground. Please refer to the section 5 Suggested ground
connection” of the BES X PRE-Installation Manual for further information.