BES X system configurations BES X Installation Manual, Rev.9, Jun 2018
28
28 P/N: 400288005
IMPORTANT NOTE: Never, for any reason, run low voltage signal cables (such as network cables)
near any kind of high voltage source.
3.1 - No console present
This is the simplest configuration. On each pair of lanes there will be installed:
the camera (Q-Vision or T/M-Vision);
the pinspotter interface;
other optional LCOM devices (Bumper interface, Q-FOUL, TMR, etc…);
one 4HD/5HD-HUB;
one 4HD/5HD-CPU;
the overhead monitors (i.e.: two overhead monitors).
The camera, the pinspotter interface and the other optional LCOM devices are connected to the 4HD/5HD-
HUB via the LCOM cable (Refer to section “6 LCOM Line for further information).
The L1 port of the 4HD/5HD-CPU is connected to the L1 port of the 4HD/5HD-HUB via a network cable.
Each overhead monitor is connected to the proper port of the 4HD/5HD-CPU unit with a HDMI cable. If the
monitors does not support commands by the HDMI, a serial communication cable (P/N: 288401007) has to
be installed between the overhead monitor and the 4HD/5HD-CPU in order to be controlled directly from a
ConquerorPRO computer.