EB200 Manual TRACe subsystem
4052.2000.02 4.116 E-7
. :LIMit
. . [:UPPer] <trace_name>, <numeric_value>|MINimum|MAXimum
Setting the limit of a trace. If the limit is exceeded, the Limit exceeded Flag will be set in the
STATus:TRACe register.
Error message:
If the trace name is unknown, an error -141, "Invalid character data" will be generated.
Parameters:
<trace_name> see TRACe[:DATA]?
<numeric_value> limit in percent of the maximum trace length
MINimum|MAXimum setting the least|greatest limit
*RST state:
50 PCT
Example:
TRACe:LIMit MTRACE, 50 PCT
. . [:UPPer]? <trace_name>[,MINimum|MAXimum]
Query of trace limit
Error message:
If the trace name is unknown, an error -141, "Invalid character data" will be generated.
Parameters:
<trace_name> see TRACe[:DATA]?
no further parameter query of current limit
MINimum|MAXimum query of least|greatest limit
Result:
Limit in percent of maximum trace length
Example:
TRACe:LIMit? MTRACE -> 50