EB200 Manual  Remote control 
4052.2000.02 4.16  E-7 
 
*IDN? 
 IDENTIFICATION QUERY queries unit about identification.  
  The output of the unit can be: 
 "ROHDE&SCHWARZ,EB200,105.050/003,01.00-4052.4654.00 
 
  105050/003  is the serial number of the unit  
  02.72  is the version number of the firmware of the main processor (EB200P1)  
  4052.4654.00  is the ident number of the software for the main processor (EB200P1)  
 
*IST? 
  INDIVIDUAL STATUS QUERY states the contents of the IST flags in decimal form (0 | 1).  
 
*OPC 
  OPERATION COMPLETE sets the bit in the event-status register to 0 if all previous commands 
were carried out. This bit can be used for triggering a service request (see "Status reporting system" 
on page 127).  
 
*OPC? 
  OPERATION COMPLETE QUERY writes the message ’1’ into the output buffer as soon as all 
previous commands were carried out (see "Status reporting system" on page 127).  
 
*OPT? 
  OPTION IDENTIFICATION QUERY queries about the options in the unit and outputs a list of 
installed options. The options are separated by a comma.  
 
  Explanation for the output characters: 
 
  SU = internal IF panorama module  
  BP = Battery Pack 
  DS = RF Spectrum DIGI-Scan (software option) 
ER = Expansion RAM 
CM = Coverage Measurement (software option) 
FS = Field Strength Measurement (software option) 
 
Example of response from the unit: 0,BP,DS,ER,0,FS 
 
*PRE 0 to 255  
  PARALLEL POLL ENABLE sets parallel poll enable register to the value indicated. Query *PRE? 
returns the contents of the parallel poll enable register in decimal form.