Adjusting the holding tension on the boom
central section
ü
The boom is folded in.
u
T
urn the nut [4] on the 2nd hydraulic
cylinder.
Fig. 65: Boom central section
Observe:
Increase tension: Screw out threaded rod.
Reduce tension: Screw in threaded rod.
Adjusting the holding tension on the boom
end section
ü
The boom is folded in.
u
T
urn the nut [5] on the 3rd hydraulic
cylinder.
Fig. 66: Boom end section
10.9 Electrics, electronic system
n
Electric fuses
The power supply of the machine is fuse-protected via the ISOBUS cable of the tractor.
The
ISOBUS cable features a 50 ampere and a 30 ampere fuse for overload protection. The fuses
can be found in the electrical cabinet on the left side of the machine (viewed in the direction of travel).