EasyManua.ls Logo

Rauch AERO GT 60.1 - Checking Other Components; Hydraulic Component; Hydraulic Motors

Rauch AERO GT 60.1
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
u
Open the filling screw [2].
u
Fill the transmission [3] with 0.6 liters of transmission oil.
u
Close the filling screw [2] again.
The oil in the transmission of the V
ario drive has been changed.
Carry out a test run:
Let the blower drive run with a low PTO speed until the air in the system has been vented.
Next, increase the speed to the maximum blower speed.
10.10.7 Checking other components
n
Hydraulic component
u
Check
axial piston pumps [1], axial piston
motor [2], and oil chiller [3] on a regular
basis.
u
Check the hydraulic components for
external damage and leakage.
Fig. 81: Checking the axial piston pump, axial
piston motor
, and oil cooler
n
Hydraulic motors
10. Maintenance and service
AERO GT 60.1 5903494
119

Table of Contents

Related product manuals