u
Open the filling screw [2].
u
Fill the transmission [3] with 0.6 liters of transmission oil.
u
Close the filling screw [2] again.
The oil in the transmission of the V
ario drive has been changed.
Carry out a test run:
•
Let the blower drive run with a low PTO speed until the air in the system has been vented.
• Next, increase the speed to the maximum blower speed.
10.10.7 Checking other components
n
Hydraulic component
u
Check
axial piston pumps [1], axial piston
motor [2], and oil chiller [3] on a regular
basis.
u
Check the hydraulic components for
external damage and leakage.
Fig. 81: Checking the axial piston pump, axial
piston motor
, and oil cooler
n
Hydraulic motors
10. Maintenance and service
AERO GT 60.1 5903494