Fault Possible cause Measure
The boom packages do not
make contact in the transport
position.
The pretension of the hydraulic
cylinders is not suf
ficient.
u
Check
the clearance
between the disc spring and
the pressure plate on the
hydraulic cylinder and adjust
it, if necessary.
u
Check the joint eyes on the
hydraulic cylinder and
replace them, if necessary.
u
In case of a leak in the
hydraulic cylinder, replace
the sealing package.
The slope cannot be adjusted.
The boom is locked on the
pendulum frame when it is
folded out.
u
Check the pendulum frame
locking mechanism and
open it using the terminal in
the Boom folding menu, if
necessary.
The metering shaft of a section
does not stop after it has been
switched of
f.
The hydraulic valve on the
metering drive is without
function.
u
Check
the valve and replace
it, if necessary.
Power supply, plug connectors,
and/or wiring harness to the
switching solenoid on the drive
motor defective.
u
Visit an authorized
workshop.
The metering shaft cannot be
switched back on.
The hydraulic valve on the
metering drive is without
function.
u
Check the valve and replace
it, if necessary.
Power supply, plug connectors,
and/or wiring harness to the
switching solenoid on the drive
motor defective.
u
Visit an authorized
workshop.
The noise level on the blower
drive is higher
.
Rubber elements are defective.
u
Close
rubber element in the
claw coupling on the blower
drive.
u
Check rubber element in
claw coupling and replace it,
if necessary.
9. Faults and possible causes