CHAPTER 3
10 ISOBUS Product Control Installation & Operation Manual
MOUNT THE CONTROL VALVE
1. Mount the motorized control valve in the main hose line between the flow meter and the booms, with the
motor housing in the upright position. Refer to Figure 1 on page 9.
2. Connect the flow control cable connectors to the boom valves, flow meter, and motorized control valve. The
table below tells white wire color(s) connect to each valve:
BY-PASS PLUMBING
For flow less than 3 GPM [11 lit/min] the motorized control valve must be mounted in a by-pass line.
Wire Colors Labeled
Connect to
Valve
Black or
Gray
Valve #1 1
Brown Valve #2 2
Blue Valve #3 3
Black with white stripe Valve #4 4
Brown with a white stripe Valve #5 5
Blue with a white stripe Valve #6 6
White with a black stripe Valve #7 7
White with a brown stripe Valve #8 8
White with a blue stripe Valve #9 9
Pink or
Violet
Valve #10 10
Yellow with a white stripe or
Gray
Valve #11 11
Green with white stripe or
Brown
Valve #12 12
Red with white stripe or
Blue
Valve #13 13
White with yellow stripe or
Black with white stripe
Valve #14 14
White with a green stripe or
Brown with a white stripe
Valve #15 15
White with a red stripe or
Blue with a white stripe
Valve #16 16

Table of Contents