Manual No. 016-0171-362 Rev. F 67
RPM METER CAL
The machine should be configured with a magnetic pickup coil mounted near the bolt heads on the spinner.
Calculate the meter cal by multiplying the number of pulses (bolt heads) per revolution by 10.
FOR EXAMPLE:
If the number of pulses per revolution is 4:
then the value for the Meter Cal would be 40.
RPM TARGET
The Rate Cal should be set to the desired RPM of the spinner.
MeterCal N 10×=
410× 40=

Table of Contents