EasyManuals Logo

Raven ISOBUS Product Control User Manual

Default Icon
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
CHAPTER 4
20 ISOBUS Product Control Installation & Operation Manual
SPEED CAL
A speed cal input is enabled if the controller is being used in conjunction with a switchbox that supports speed
input calibration. The speed cal value is used to adjust in the incoming signal from the speed source. To set the
speed cal value, start with 600 as an initial value. On the totals screen, reset the distance value to 0. Drive one mile
while slowly decelerating and accelerating. If the distance reading is not between 5,260 feet and 5,300 feet (995
meters and 1,005 meters), use the following calculation to determine the speed cal value:
Current Speed Cal x Known Distance Traveled / Distance Displayed on Total Screens = Adjusted Speed Cal (EQ 1)
PUMP RPM CAL
The pump RPM cal is used to calibrate the pump on the machine. Enter the number of pulses sensed per
revolution of the fan or pump. These values are used for monitoring purposes only. There is no control based on
these values or the monitored RPM of the pump. When a non-zero value is entered for pump RPM cal, a pump
RPM will display on the home screen.
VALVE CAL
Select the “Valve Cal” button on the Product Control Calibration screen to display the valve calibration screen for
the product control valve or the hydraulic control valve controlling the speed of a belt or auger system.
NOTE: To accept the currently displayed settings, or once settings have been adjusted properly, select the
“OK” button in the lower right corner of the display to return to the Product Calibration display.
VALVE TYPE
Select the type of control valve used to control the product application. Choose between a standard, fast, fast
close, PWM, or PWM close valve for this setting.
NOTE: If a pulse width modulation (PWM) type valve is selected, additional settings will be displayed on the
Valve Calibration screen. See the Pulse Width Modulation Valve Setup section on page 25 for a
description of these settings.
VALVE CAL
NOTE: If the dual loop control feature is enabled, the valve cal value will be replaced by the flow cal value.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raven ISOBUS Product Control and is the answer not in the manual?

Raven ISOBUS Product Control Specifications

General IconGeneral
BrandRaven
ModelISOBUS Product Control
CategoryControl Unit
LanguageEnglish

Related product manuals