Manual No. 016-0171-362 Rev. F 31
ISOBUS PRODUCT CONTROL NODE CALIBRATION
STANDBY PRESSURE (PWM VALVES ONLY)
The standby pressure enable section allows the operator to toggle the standby pressure feature on or off and
enter a minimum pressure to maintain all sections or the master switch is turned off. Refer to Preset PWM section
on page 28 for information on the standby pressure value.
NOTE: To enable the standby pressure feature, the product control system must have a PWM valve
controlling a liquid application system and a pressure transducer connected to the control node. If
these requirements are not met, standby pressure will automatically be disabled. When enabled, the
standby pressure setting will replace the Preset PWM setting on the Valve Calibration screen.
HIGH SIDE DRIVE
To ensure proper functionality, the high side drive option should be enabled when a PWM boost box is installed.
RATE 1/RATE 2
Rate 1 and Rate 2 values allow the increase and decrease buttons (+/-) on the Home screen to be replaced with
Rate 1 and Rate 2 buttons, allowing the operator to quickly change between two set rates.
To make Rate 1 and Rate 2 buttons available, the following conditions must be met:
Desired rates for Rate 1 and Rate 2 must be entered (non-zero values)
Control mode must be set to Auto.