OPERATION
48
Signals
Signal Lists
A signal list allows you to store and recall frequencies of interest along with additional information such
as signal amplitude, bandwidth, threat level, location, and any other comments which may be
important. With the OSCOR, you have the capability to automatically generate signal lists, merge signals
from multiple databases, add or delete signals from an existing database, or edit the information for any
given signal all on the OSCOR unit itself.
The signal list parameters that are automatically identified by this functionality include:
Frequency Peak of the signal within the measured bandwidth window
dBm Signal Level in dBm
Bandwidth The measured Bandwidth of the signal between the signal threshold levels (this
bandwidth may vary depending on the modulation and detected signal characteristics)
Date The date and time the signal was identified in the signal list. Note: This is not the actual
time that a signal was detected within a peak trace.
Last Seen, Count these fields are automatically populated by the Mask function (see page 43).
Location, Threat, Comments – these are fields that can be edited by the user for later analysis.