60
Notes
- The span and bandwidth of the spectral display can be changed while viewing a Live Raster
Waterfall. However, whenever the spectral display is changed, the waterfall data will be cleared
and a new waterfall will begin, unless Detail Zoom (see page 45) is turned on.
- The speed with which the Live Raster Waterfall data is captured and displayed will vary
depending on the span of the RF spectrum; the narrower the span, the more quickly the data
will be captured and displayed.
- Once the size of the Live Raster Waterfall has exceeded the memory buffer size, older traces will
be discarded for each new trace added.
- If the realtime trace is not displayed, turning on the Live Raster Waterfall will also automatically
turn on the realtime trace.
Viewing a Live Raster Waterfall Full Screen
The waterfall display from a Live Raster Waterfall can be viewed full screen.
1. While the Live Raster Waterfall is displayed and collecting date, select the Full Screen icon from
the Live Raster Sub-Menu.
2. To close the full screen waterfall display and return to normal viewing, select Close or press F6.
Saving a Live Raster Waterfall
The waterfall display from a Live Raster Waterfall can be saved as a .png file for inserting into reports.
1. While the Live Raster Waterfall is displayed and collecting data, select the Save icon from the
Live Raster Sub-Menu.
2. In the dialog box that appears, select a location (either a USB flash drive or compact flash card)
and type a file name for the stored .png file. Select OK or press F5.
Notes
- The Live Raster Waterfall cannot be saved while viewing full screen; you must return to normal
viewing in order to have access to the Save icon.
Opening a Saved Live Raster Waterfall
Previously saved Live Raster Waterfalls can be opened on the OSCOR unit for review.
3. From the Main Menu, select Waterfall or press F4.