Bit Switches
D432/D433 84 SM
Communication Switch 10 [SP No. 1-104-017]
No FUNCTION COMMENTS
0-7
Memory transmission:
Maximum number of dialing
attempts to the same
destination
01 – FE (Hex) times
Communication Switch 11 – Not used (do not change the settings.)
Communication Switch 12 [SP No. 1-104-019]
No FUNCTION COMMENTS
0-7
Memory transmission: Interval
between dialing attempts to
the same destination
01 – FF (Hex) minutes
Communication Switch 13 – Not used (do not change the settings.)
Communication Switch 14 [SP No. 1-104-021]
No FUNCTION COMMENTS
0
Inch-to-mm conversion during
transmission
0: Disabled 1: Enabled
0: In immediate transmission, data scanned in inch
format are transmitted without conversion.
In memory transmission, data stored in the SAF
memory in mm format are transmitted without
conversion.
Note: When storing the scanned data into SAF
memory, the fax unit always converts the data into
mm format.
1: The machine converts the scanned data or
stored data in the SAF memory to the format
which was specified in the set-up protocol