EasyManuals Logo

Ricoh Aficio MP C2030 Service Manual

Ricoh Aficio MP C2030
1171 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1137 background imageLoading...
Page #1137 background image
NCU Parameters
SM 111 D432/D433
D432/D433
Fax Option
Type
C2550/C2530
Address Function Unit Remarks
680543 Country dial tone detection time
680544
Country dial tone reset time
(LOW)
680545
Country dial tone reset time
(HIGH)
20 ms
If 680543 contains FF,
the machine pauses for
the pause time (680548 /
680549).
680546
Country dial tone continuous tone
time
- -
680547
Country dial tone permissible drop
time
680548 Country dial wait interval (LOW)
680549 Country dial wait interval (HIGH)
20 ms -
68054A
Time between opening or closing
the DO relay and opening the
OHDI relay
1 ms
See Notes 3, 6 and 8.
SP2-103-012
(parameter 11).
68054B Break time for pulse dialing 1 ms
See Note 3.
SP2-103-013
(parameter 12).
68054C Make time for pulse dialing 1 ms
See Note 3.
SP2-103-014
(parameter 13).
68054D
Time between final OHDI relay
closure and DO relay opening or
closing
1 ms
See Notes 3, 6 and 8.
SP2-103-015
(parameter 14).
This parameter is only
valid in Europe.
68054E
Minimum pause between dialed
digits (pulse dial mode)
20 ms
See Note 3 and 8.
SP2-103-016
(parameter 15).

Table of Contents

Other manuals for Ricoh Aficio MP C2030

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh Aficio MP C2030 and is the answer not in the manual?

Ricoh Aficio MP C2030 Specifications

General IconGeneral
BrandRicoh
ModelAficio MP C2030
CategoryAll in One Printer
LanguageEnglish

Related product manuals