Technical Bulletin PAGE: 7/8
Model: Aries-P1.5/C1.5 Date: 15-Jul-11 No.: RM077042a
Note for customers who already use multiple fusing units before installing new firmware
The following must be done by service technicians
1. After the new firmware is installed, the default fusing unit counter (the one which was used
when new firmware was installed) will be used as the PM counter. When the fusing unit is
replaced with another one, the default fusing unit counter will be saved as “Unit 1”
2. If the customer has multiple fusing units already, input the counter values for each fusing unit
from SP1-210-016 to SP1-210-028, from SP1-210-029 to SP1-210-041, and from SP1-210-
042 to SP1-210-054, for “Unit 2”, “Unit 3” and “Unit 4”, respectively, in order to carry on each
counter value.
3. In order to clear the counter value for fusing unit, execute SP 7-622-115 after replacing to a
brand new fusing unit.
Install the fusing unit and close the front
d
Specify the Fusing Unit Number
Open the front doors. (Leave the doors open
to prevent the system from activating.)
Start
After installing the Fusing Unit, input the counter values on the decal into the SP for the selected Fusing unit.
Example) If a fusing unit assigned as Fusing Unit #2 for Machine #1 were to be assigned as Fusing Unit #3 for
Machine #2:
Transcribe the Machine #1 PM counter values (1-210-016 to 1-210-028) onto the decal, install the fusing unit in
Machine #2, and input those values into the Machine #2 PM counters (1-210-029 to 1-210-041).
Machine 1
Unit 2
Machine 2
Unit 3
Fusing Unit: Distance Counter 1-210-016 1-210-029
Hot Roller: Distance Counter 1-210-017 1-210-030
Fusing Belt: Distance Counter 1-210-018 1-210-031
Pressure Roller: Distance Counter 1-210-019 1-210-032
Thermister1 2 3: Distance Counter 1-210-020 1-210-033
Web Cleaning: Distance Counter 1-210-021 1-210-034
Fusing Unit: Pg Counter 1-210-022 1-210-035
Hot Roller: Pg Counter 1-210-023 1-210-036
Fusing Belt: Pg Counter 1-210-024 1-210-037
Pressure Roller: Pg Counter 1-210-025 1-210-038
Thermistor1 2 3: Pg Counter 1-210-026 1-210-039
Web Cleaning: Pg Counter 1-210-027 1-210-040
Web Total: Page Counter 1-210-028
1-210-041