Technical Bulletin PAGE: 3/4
Model: Aries-P1.5/C1.5, AG-P1/C1, AGL-P1/C1
Adjustment procedure for Sub Scan direction
1. Execute MUSIC and print the affected job.
2. Measure the amount of misalignment (in millimeter or micrometer or inch) in Sub Scan
direction using a magnifier for C, M and Y.
3. Use the Excel file embedded in the Appendix of this RTB to convert the measurements
into number of dots and sub dots. Input the values derived to the following SP.
4. Print the affected job and check the results with the magnifier.
5. Repeat steps 2 through 4 until the colors align.
NOTE:
Executing MUSIC resets the SP values to ‘0’ (default).
IMPORTANT:
Make sure to reset the SP values to ‘0’ (default) after printing the affected job.
This adjustment should be performed temporarily only for jobs that require
adjustments based on customer request. The effect is temporal because the
image creation process is constantly affected by the operational environment as
mentioned in ‘CAUSE’.