EasyManua.ls Logo

Ricoh pro c901 - Page 532

Ricoh pro c901
586 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Bulletin PAGE: 4/4
Model: Aries-P1.5/C1.5, AG-P1/C1, AGL-P1/C1
Date: 19-Mar-14
No.: RM077109
Example
Following is an example of adjusting a misalignment of 25 micrometers in both Main and
Sub Scan directions in Cyan.
Dot/sub dot to micrometer conversion rate:
1 Dot = 21.16 micrometers
1 Sub dot = 1.3 micrometers
1. Main Scan direction
SP2-191-004 Line Position Adj. Offset C Main Regist (dot)
+ 1 dot (= 21.16 micrometers)
SP2-191-007 Line Position Adj. Offset C Main Regist (sub dot)
+ 3 sub dots (= 3.9 micrometers)
2. Sub Scan direction
SP2-101-017 Color Interval Registration Adjustment Sub Scan:Bk-C:Drum Motor Adj’
+ 25 micrometers
APPENDIX
Double-click to open the embedded Excel file below. Adjustment value is calculated
automatically by inputting the value of misalignment measured with the magnifier.
Length of
misalignment.xls
RM077109 - length of misalignment.xls

Table of Contents

Other manuals for Ricoh pro c901

Related product manuals