Technical Bulletin PAGE: 40/44
Model: Aries-P1.5/C1.5 Date: 17-Feb-11 No.: RM077018
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
221. Check or clear obstacles around the motor drive
mechanism.
222. Check the harness connection.
223. Replace the stack plate HP sensor (center).
224. Replace the stack plate motor (center).
225. Replace the finisher main board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Stack Plate Motor Error 2: Front Motor (B830)
The stack plate HP sensor (front) does not activate within 500 ms
after the motor turns on.
The 1st detection failure causes a jam error, and the 2nd failure
causes this SC code.
If the motor is operating
Front stack plate HP sensor harness loose, broken, defective
Front stack plate HP sensor defective
If the motor is not operating:
Motor blocked by an obstruction
Motor harness loose, broken, defective
Motor defective
Finisher main board defective
747 B
226. Check or clear obstacles around the motor drive
mechanism.
227. Check the harness connection.
228. Replace the stack plate HP sensor (front).
229. Replace the stack plate motor (front).
230. Replace the finisher main board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Stack Plate Motor Error 3: Rear Motor (B830)
The stack plate HP sensor (rear) does not activate within 500 ms
after the motor turns on. The 1st detection failure causes a jam
error, and the 2nd failure causes this SC code.
748 B
If the motor is operating
Rear stack plate HP sensor harness loose, broken, defective
Rear stack plate HP sensor defective
If the motor is not operating:
Motor blocked by an obstruction
Motor harness loose, broken, defective
Motor defective
Finisher main board defective