Technical Bulletin PAGE: 43/44
Model: Aries-P1.5/C1.5 Date: 17-Feb-11 No.: RM077018
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Finisher punch motor error: 3K Finisher B830
The punch HP sensor is not activated within the specified time
after the punch motor turned on.
The 1st detection failure issues a jam error, and the 2nd failure
issues this SC code.
Punch HP sensor disconnected, defective
Punch motor disconnected or defective
Punch motor overload due to obstruction
760 B
255. Check the connections and cables for the punch motor and
HP sensor.
256. Check for blockages in the punch motor mechanism.
257. Replace the punch HP sensor and/or punch motor
258. Replace the finisher main board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Fold Plate Motor Error: Booklet Finisher D434
The fold plate moves but is not detected at the home position
within the specified time.
The 1st detection failure issues a jam error, and the 2nd failure
issues this SC code.
Fold plate HP sensor disconnected, defective
Fold plate motor disconnected, defective
Fold plate motor overloaded due to obstruction.
761 B
259. Check the connections and cables for the fold plate motor
and HP sensor.
260. Check for blockages in the folder plate motor mechanism.
261. Replace the fold plate HP sensor and/or fold plate motor
262. Replace the finisher main board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Fold Unit Bottom Fence Lift Motor Error: Booklet Finisher D434
The fold unit bottom fence did not return to the home position
within the specified time.
765 B
Fold bottom fence mechanism overloaded due to an
obstruction
Fold bottom fence HP sensor connector loose, broken,
defective
Fold bottom fence HP sensor defective
Fold bottom fence lift motor connector loose, broken, defective
Fold bottom fence lift motor defective
Main control board defective