Technical Bulletin PAGE: 44/44
Model: Aries-P1.5/C1.5 Date: 17-Feb-11 No.: RM077018
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
263. Check or clear obstacles around the motor drive
mechanism.
264. Check the harness connection.
265. Replace the fold bottom fence HP sensor.
266. Replace the fold bottom fence lift motor.
267. Replace the finisher main board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Clamp Roller Retraction Motor: Booklet Finisher D434
The clamp roller did not return to the home position within the
specified time.
Clamp roller mechanism overloaded due to an obstruction
Clamp roller HP sensor connector loose, broken, defective
Clamp roller HP sensor defective
Clamp roller retraction motor connector loose, broken,
defective
Clamp roller retraction motor defective
Main control board defective
766 B
268. Check or clear obstacles around the motor drive
mechanism.
269. Check the harness connection.
270. Replace the clamp roller HP sensor.
271. Replace the clamp roller retraction motor.
272. Replace the finisher main board.