Chapter 2 Command System RIGOL
MSO1000Z/DS1000Z Programming Guide 2-165
:TRIGger:PULSe:WHEN
Syntax
:TRIGger:PULSe:WHEN <when>
:TRIGger:PULSe:WHEN?
Description
Set or query the trigger condition in pulse width trigger.
Parameter
Name
Type
Range
Default
<when>
Discrete
{PGReater|PLESs|NGReater|
NLESs|PGLess|NGLess}
PGReater
Explanation
PGReater/PLESs: you need to specify a pulse width (refer
to :TRIGger:PULSe:WIDTh). The oscilloscope triggers when the positive pulse width
of the input signal is greater/lower than the specified Pulse Width.
NGReater/NLESs: you need to specify a pulse width (refer
to :TRIGger:PULSe:WIDTh). The oscilloscope triggers when the negative pulse width
of the input signal is greater/lower than the specified Pulse Width.
PGLess/NGLess: you need to specify an upper (refer to :TRIGger:PULSe:UWIDth)
and a lower (refer to :TRIGger:PULSe:LWIDth) pulse width. The oscilloscope triggers
when the positive/negative pulse width of the input signal is greater than the
specified lower pulse width and lower than the upper pulse width.
Return
Format
The query returns PGR, PLES, NGR, NLES, PGL, or NGL.
Example
:TRIGger:PULSe:WHEN NLESs /*Set the trigger condition to NLESs*/
:TRIGger:PULSe:WHEN? /*The query returns NELS*/
:TRIGger:PULSe:WIDTh
Syntax
:TRIGger:PULSe:WIDTh <width>
:TRIGger:PULSe:WIDTh?
Description
Set or query the pulse width in pulse width trigger. The default unit is s.
Parameter
Name
Type
Range
Default
<width>
Real
8ns to 10s
PGReater, NGReater: 1μs
PLESs, NLESs: 2μs
Explanation
This command is available when the trigger condition (refer to :TRIGger:PULSe:WHEN) is
PGReater, PLESs, NGReater, and NLESs.
Return
Format
The query returns the pulse width in scientific notation.
Example
:TRIGger:PULSe:WIDTh 0.000003 /*Set the pulse width to 3μs*/
:TRIGger:PULSe:WIDTh? /*The query returns3.000000e-06*/

Table of Contents

Other manuals for Rigol DS1104Z Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS1104Z Plus and is the answer not in the manual?

Rigol DS1104Z Plus Specifications

General IconGeneral
Bandwidth100 MHz
Channels4
Sample Rate1 GSa/s
Memory Depth24 Mpts
Waveform Capture Rate30, 000 wfms/s
Vertical Sensitivity1 mV/div to 10 V/div
Timebase Range5 ns/div to 50 s/div
ConnectivityUSB Host, USB Device, LAN, AUX
Vertical Resolution8 bits
Power Supply100-240 V AC, 45-440 Hz
Display7 inch TFT LCD
Trigger TypesEdge, Pulse, Video, Slope
Input Impedance1 MΩ ± 2%