3.4. DESCRIPTION OF THE ELECTRICAL DEVICES
T
he fi
g
ure shows the
p
ositionin
g
of the devices on board of the machine.
A)
g
ear motor: it enables the movement of the left conve
y
or belt.
B)
g
ear motor: it enables the movement of the ri
g
ht conve
y
or belt.
C) Gear motor: activates the movement of the entrance carrier (O
p
tional).
D) "Entrance
g
uard" limit switch: detects the o
p
enin
g
of the
p
rotective
g
uard u
p
on entr
y
.
E) "Exit
g
uard" limit switch: detects the o
p
enin
g
of the
p
rotective
g
uard u
p
on exit.
F) “Flap cover” photocell: detects the passage of the product and commands the functioning of the rear
fla
p
cover.
G) “Tape closure” photocell: detects the passage of the product and commands the closure of the
conve
y
or belts.
H) “Downward bridge” photocell: detects the passage of the product and commands the descent of the
liftin
g
brid
g
e.
I) "Brid
g
e u
p
" sensor: detects the com
p
lete liftin
g
of the liftin
g
brid
g
e.
J
) "Brid
g
e down" limit switch: detects the descent of the liftin
g
brid
g
e on the
p
roduct.
K) "Upper head tape deficiency" photocell: detects that the tape on the upper taping unit head is running
out.
L) "Lower head tape deficiency" photocell: detects that the tape on the lower taping unit head is running
out.
M) "U
pp
er head ta
p
e breaka
g
e" sensor: detects the breaka
g
e/end of the ta
p
e on the u
pp
er ta
p
in
g
unit.
N) “O
p
en ta
p
es” sensor: detects the com
p
lete o
p
enin
g
of the conve
y
or belts.
O) "Lower head ta
p
e breaka
g
e" sensor: detects the breaka
g
e/end of the ta
p
e on the lower ta
p
in
g
unit.